Data-Loggers for Temperature & Humidity
Docking Stations
21 CFR Part 11 Softwares
Calibrators
Calibration Services
Case Studies
Certificates & Documents


Adobe Acrobat Reader

Optimized for

Products

Temperature and temperature/humidity data-loggers

PyroButton - We offer the smallest (17mm x 6mm), most accurate, having the best reproducibility, and cost effective calibrated data-loggers.

Key Benefits to the User

  • Each data-logger is calibrated at 3-points relative to NIST reference and the calibration is verified prior to shipment
  • Each measurement is corrected relative to the calibration curve.
  • Data integrity protection for 21 CFR Part 11 requirement.
  • Calibration corrections are automatically calculated for each temperature measurement
  • Certificate of Calibration is included for each data-logger
  • The data-loggers can be chemically sterilized & depyrogenated due to their hermetically sealed stainless steel housing
  • High Throughput Adapters are available, which hold 8, 16, 32, or 50 data-loggers for simultaneous programming or downloading of data
  • The data-loggers can be integrated to Self-powered communication network for global data management
  • Critical Control Points can be determined by utilizing Computer Aided Temperature distribution mapping program
  • Data-acquisition simulation ensures optimized battery life span
  • PyroButton is easy to learn and simple to operate

Return-On-Purchase-Investment (ROPI)

  • Low purchase cost ensures rapid Return-On-Purchase-Investment
  • Low calibration cost ensures low cost of compliance
  • Low maintenance cost ensures low cost of operation
  • On-line training ensures low cost of implementation
  • 21 CFR Part 11 compliance ensures investment security

Key features

  • Food compatibility is approved by the European Community and the US FDA
  • Rugged stainless steel housing - resistant to water, chemicals, shock, physical stress; it can be sterilized and chemically depyrogenated
  • Calibrated at 3 points
  • Size 6 mm x 17 mm (button type)
  • Battery life expectancy up to 10 years
  • No external charger is required
  • Temperature range -40 to +85°C or 0 to 125°C (depending on the model)
  • Temperature resolution ±0.0625°C or ±0.5°C (depending on the model)
  • Temperature accuracy ±0.1°C or ±0.5°C with calibration correction
  • Sampling rate 1 sec to 273 hr or 1 min. & to 255 min (depending on the model)
  • Data acquisition capacity 8196 or 2048 (depending on the model & resolution settings)
  • Three measure modes: continuous, start/stop, or start/preset
  • PyroButton-Basic, or PyroButton-Standard, or PyroButton-SQL is required for program upload or data download
  • All three (3) software are 21 CFR Part 11 compliant
  • Graphical output of data and Excel compatibility
  • Browser & wizard technology have been integrated for easy learn and simple operation
  • Plus many more features
 
Title View Download
iButton vs. PyroButton comparison chart HTML Pdf file Pdf file (134 KB)
Data-logger comparison chart HTML Pdf file Pdf file (96 KB)

 

Product code Description List price (USD)  
100-IBE-001-100 PyroButton-G - Self-powered temperature device (-40 to +85°C),
Temperature resolution ±0.5°C, Temperature accuracy ±0.5°C
Calibrated at 3-points relative to NIST reference.
Each measurement is corrected relative to the calibration curve.
Data integrity protection for 21 CFR Part 11 requirement.
115
/each 
 
100-IBE-003-100 PyroButton-L - Self-powered temperature device (-40 to +85°C);
Temperature resolution ±0.0625°C, Temperature accuracy ±0.1°C
Calibrated at 3-points relative to NIST reference.
Each measurement is corrected relative to the calibration curve.
Data integrity protection for 21 CFR Part 11 requirement.
155
/each 
 
100-IBE-004-100 PyroButton-T - Self-powered temperature device (0 to 125°C),
Temperature resolution ±0.0625°C, Temperature accuracy ±0.1°C
Calibrated at 3-points relative to NIST reference.
Each measurement is corrected relative to the calibration curve.
Data integrity protection for 21 CFR Part 11 requirement.
225
/each 
 
100-IBE-005-100 PyroButton-TH - Self-powered temperature/humidity data-logger
Temperature (-20 to +85°C), ±0.0625°C resolution, ±0.1°C accuracy
Humidity (10 - 90% RH), resolution ± 0.04% RH, ±2% RH accuracy
Calibrated at 3-temperature points relative to NIST reference and 3-humidity points.
Each measurement is corrected relative to the calibration curve.
Data integrity protection for 21 CFR Part 11 requirement.
325
/each 
 
 





Back Back
----------------------------------